Detail: 1250GF3 400V 3300V 10500V HFO POWER PLATN with Low
Emissions
Descrition:
Utilities and Independent power producers use our 0~ 60 MW power
plants to generate power to the grids in the undeveloped,
developing world and in remote areas. These plants are flexible to
follow the actual load and produce the necessary electricity
typically from diesel oil, heavy fuel oil, bio diesel and bi-fuel.
High efficiency, low emissions and proven long-term reliability
make our diesel oil power plants, heavy fuel oil power plant, and
bi-fuel power plants suitable for baseload applications. Depending
on your current load profile, ambient conditions and what fuel is
available ( diesel oil, heavy fuel oil, crude oil etc.) we make
sure you will get the most productive and cost-effective solution
Our company offers a wide range of engines for stationary power
generation, where their competitive first-cost, high energy
efficiencies and low life-cycle costs underwrite success, ranges
from baseload power plant, peaking power plant to industrial
self-captive power plant in cement, textile, mining or oil and gas
industries etc.
These engines comfortably meet current emission standards, and are
able to comply with more strict national codes by adding emission
reduction equipment.
.
Peaking power plant
Our power plants can start and ramp up to full load very rapidly,
in less than minutes. They can start upon a grid or a large power
plant after shut down, without any external input of energy. Due to
very high simple cycle efficiency on part and full load, they can
provide very competitive power regulation and spinning reserve
services to large grids, which both require operation on partial
load. These very same plants can be used for peaking services
during peak electricity demand hours. Due to the high efficiencies
and consequential low generation costs, our power plants create
more revenues for its operators. The main fuel can be gas, LFO, HFO
or a multi-fuel combination of these.
Industrial self-captive power plant
Many energy intensive industries find it attractive to improve
their competitiveness by producing their energy in a local captive
power plant and thereby reduce the energy costs. In some areas this
improves also the availability of energy due to unstable grid
conditions. Many of the industrial power plants operate, producing
electricity and utilizing the waste heat of the generation process
to produce steam, hot water and cooling. All this we can do for
you.
Applications:
cement, textile, mining or oil and gas industries etc.
Competitive Advantage:
Our experts in application engineering and project management are
the key to achieving very short construction times , builds
turn-key power plant with an output up to 60MW as base load power
plant, peaking power plant or industrial self-captive power plant
in cement, textile, mining or oil and gas industries etc. The power
fuel can be diesel oil, bio-diesel, heavy fuel oil ( HFO) or
bi-fuel
- - - -
G300 Statinary Generating Sets Main Specification |
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 |
Rated power, KW | 1000 | 1250 | 1350 | 1400 |
Overload , KW | 1100 | 1375 | 1485 | 1540 |
Rated voltage, V | 400/ 415/ 440/ 3300/ 6300/ 10500/ 13800 |
Rated current , A | | | | | | | | |
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging |
Phase | 3 |
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 |
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 |
2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | 0.5 | 0.5 |
Frequency fluctuation rate, % | 0.5 | 0.5 |
Stable voltage regulating rate, % | 1.0 | 1.0 |
Transient voltage regulating rate, % | + 20, -15 | + 20, -15 |
Stable Frequency fluctuation rate, % | 3 | 0.5 |
Transient frequency regulating rate, % | + 12, -10 |
Stablizing time, voltage , S | 4 |
Stablizing time, frequency , S | 3 |
voltage regulating method | automatic and munual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressue lubricating |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 3880* 2150* 3180 | 8470* 2360* 3060 |
Weight, Kg | 30000 | 35000 | 38000 |
- - - -
- - - -
G300 Statinary Generating Sets Main Specification |
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 |
1500 | 1600 | 1800 | 2000 |
1650 | 1760 | 1980 | 2200 |
400/ 415/ 440/ 3300/ 6300/ 10500/ 13800 |
| | | | | | | |
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging |
3 |
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 |
G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator |
0.5 |
0.5 |
1.0 |
20, -15 |
0.5 |
+ 20, -15 |
5 |
4 |
automatic and munual |
manual |
compressed air |
pressue lubricating |
water cooling |
flexible |
8470* 2360* 3060 |
38000 | 42560 |
- - - -
Remark 1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard
conditions
air temperature : 25
total barometric pressure 100kpa
charge air coolant temperature 25
relative humidity 30%
If test ambient conditions are not same as the standard ambient
conditions, the power and fuel consumptions should be revised
according to GB/ T6072.1-2000
3.The generator set can operate under overload, intermittently for
1 hour every 12h, the fuel injection quantity is usualy locked in
the rated power position
- - - -
GN8320 Stationary Generating Sets Main Specification |
Model | 2400GF | 2500GF |
Rated power, KW | 2400 | 2500 |
Overload , KW | 2640 | 2750 |
Rated voltage, V | 400 | 415 | 3300 | 6300 | 10500 | 400 | 415 |
3300 | 6300 | 10500 |
Rated current , A | 4330 | 4174 | 525 | 275 | 165 | 4511 | 4348 |
547 | 172 | 286 |
Frequency , Hz | 50 | 50 |
Power factor | 0.8 Lagging | 0.8 Lagging |
Phase | 3 | 3 |
Diesel engine | GN832000ZD | GN8320ZD |
Rated power, KW | 2648 | 2795 |
Rated rev, rpm | 750 | 750 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | 1.0 |
Frequency fluctuation rate, % | + 12, -10 |
Stable voltage regulating rate, % | 3 |
Transient voltage regulating rate, % | + 12, -10 |
Stable Frequency fluctuation rate, % | 4 |
Transient frequency regulating rate, % | 5 |
Stabilizing time, voltage , S | + 1 |
Stabilizing time, frequency , S | + 12, -10 |
voltage regulating method | automatic and manual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressure lubricating |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 8950* 2570* 6050 |
Weight, Kg | 45000 |
- - - -
Remark 1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard
conditions
air temperature : 25
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient
conditions, the power and fuel consumptions should be revised
according to GB/ T6072.1-2000
3.The generator set can operate under overload, intermittently for
1 hour every 12h, the fuel injection quantity is usualy locked in
the rated power position
Model Number: According to the design and technical demand
Brand Name: KANGWEI
Payment Terms: T/ T, L/ C
Minimum:
Certification: CCS, BV, GL
Delivery Time: Negotiate
Supply Ablity:
|
1250GF3 400V 3300V 10500V HFO POWER PLATN with Low Emissions Images
|